Cobra Ultimate Kermel® and Lenzing® FR Firefighting Hood

30400-00-185084

Cobra Ultimate hoods are double ply and feature extra-long length that covers head, chest, shoulders and shoulder blades for enhanced protection. Flat-stitched seams eliminate bunching and won’t dig into skin. A half inch wide elastic face opening stretches to full 16" to ensure a snug fit around most SCBA masks.

Fabric Description:

Inherently flame-resistant blend of two exceptionally soft and comfortable fibers. Fabric blend offers excellent thermal insulation, providing efficient protection from heat, even in lighter weights. Interlock knit gives the fabric the finest hand and smoothest surfaces of all knits. Due to its low modulus, Kermel® fiber is silk-soft to the touch, making hoods or base layers made from it extremely comfortable. Both the Kermel® and Lenzing FR® fibers are solution-dyed navy blue during the manufacturing process, making the color an inherent part of the yarn itself, eliminating fading due to UV exposure or through repeated washing and drying. Additionally, the fabric has excellent pill and abrasion resistance, keeping the hoods or base layers looking new, even after prolonged use and repeated launderings.

Sizing:

One size fits most

Options:

Thread
Cobra hoods are available sewn with either color-coordinated (matching) or color-contrasting 100% Nomex® thread.
Direct Embroidery
100% Nomex® thread embroidered on bib. Minimum order 25 each.
Ink Heat Transfers
High resolution multi-color transfers. Minimum order 100 each.

Test Results

Fabric Performance ValuesPGI Test Results
Thermal Protective Performance (TPP)
  • As Received
22.8
  • After 5 Washings
30.0
Hood Material Burst Strength 462 N
Flame Resistance Test

After Flame (Wales x Courses)

  • As Received
0.4 sec x 0.4 sec
  • After 5 Washings
0.5 sec x 0.5 sec

Char Length (Wales x Courses)

  • As Received
44 mm x 41 mm
  • After 5 Washings
36 mm x 30 mm
Cleaning Shrinkage Resistance Test

Hood Measurement

  • After 5 Washings
0.0%

Face Opening Measurement

  • After 5 Washings
YES
Heat & Thermal Shrinkage Resistance Test

Hood Measurement

  • As Received
-0.3% to 0.0%
  • After 5 Washings
-0.3% to 0.0%

Face Opening Measurement

  • As Received
YES
  • After 5 Washings
YES
Seam Breaking Strength Test742 N
Melt or Drip When Exposed to Flame NONE

Product Line

Cobra<sup>™</sup> Ultimate<sup>™</sup> Para‑Tek FR<sup>™</sup> Tri‑Blend

Cobra Ultimate Para‑Tek FR Tri‑Blend

Cobra<sup>™</sup> Ultimate<sup>™</sup> Ara‑Tek FR<sup>™</sup> Tri‑Blend

Cobra Ultimate Ara‑Tek FR Tri‑Blend

Cobra<sup>™</sup> Ultimate<sup>™</sup> Comfort Plus<sup>™</sup> Nomex<sup>®</sup> (Meta‑Aramid) and Lenzing FR<sup>®</sup>

Cobra Ultimate Comfort Plus Nomex® (Meta‑Aramid) and Lenzing FR®

Cobra<sup>™</sup> Ultimate<sup>™</sup> PBI/Lenzing FR<sup>®</sup> with Comfort Plus<sup>™</sup> Liner

Cobra Ultimate PBI/Lenzing FR® with Comfort Plus Liner

Cobra<sup>™</sup> Ultimate<sup>™</sup> 100% Nomex<sup>®</sup> Meta‑Aramid

Cobra Ultimate 100% Nomex® Meta‑Aramid

Cobra<sup>™</sup> Ultimate<sup>™</sup> Carbon Shield<sup>™</sup>

Cobra Ultimate Carbon Shield